Skip to content
Click here to sign up to our newsletter for news on latest offers, events and expert advice.
Click here to sign up to our newsletter for news on latest offers, events and expert advice.

X-Rite i1Publish Pro 3 Plus

 

Colour Management for Imaging and Prepress

For designers, photographers, or prepress professionals who rely on accurate colour throughout a digital workflow, the i1Publish Pro 3 Plus is the must-have solution to profile and calibrate cameras, monitors, projectors, scanners, and both RGB and CMYK+ printers. Get the most colour accurate displays, prints and proofs, with repeatable results every time.

Accommodating a broad range of proficiencies and expertise, i1Publish Pro 3 Plus provides complete power and control to create the highest quality ICC profiles. Choose between a basic, wizard-driven interface, or an advanced user-driven interface to create high quality, precise, custom colour profiles.

Benefits:

  • Large aperture (8mm) gives more accurate results with better repeatability.
  • Includes polarising filter for improved profiles from textiles and other textured media.
  • Benefit from perfect printed colours every time with RGB, CMYK and CMYK + any 4 with intelligent iterative profiling technology for best quality results and advanced controls for black generation and separations.
  • Achieve true colours on all modern laptop and desktop display technologies, such as LED, Plasma, RG Phosphor, OLED and Wide Gamut.
  • Quickly check colour output quality with the ColorChecker Proof visual assessment target, included with i1Publish.
  • Correct for OBAs in paper with Optical Brightener Correction technology (when combined with i1iSis 2 automated chart reader).
  • Capture spot colours off virtually any surface – ideal for creative design or corporate brand requirements* – and keep your PANTONE libraries up-to-date, accurate and ready to use in Adobe® and Quark® creative applications with PANTONE Colour Manager for colour palette creation and swatch bridging software.

 

Specifications

i1Profiler Software Specifications
Macintosh®

  • MacOS X 10.11x, 10.12x, 10.13x, 10.14x or 10.15x (with the latest updates installed)
  • 512MB RAM (2GB recommended)
  • Intel® Core Duo Processor
  • Up to 500MB of available disk space (depending on components installed)
  • Powered USB Port
  • Monitor resolution of 1024x768 pixels or higher
  • Dual display support requires either 2 video cards or a dual head video card that supports dual video LUTs being loaded
  • DVD drive or high-speed internet connection required for software install, download and automatic software update
  • User must have administrator rights to install and uninstall application

Windows®

  • Microsoft® Windows 7® 32 or 64 bit
  • Microsoft® Windows 8® 32 or 64 bit
  • Microsoft® Windows 8.1® 32 or 64 bit
  • Microsoft® Windows 10® 32 or 64 bit
  • All operating systems require latest updates and Service Packs installed
  • 512MB RAM (2GB recommended)
  • Intel® Core 2 Duo or AMD® Athlon® XP or better CPU
  • Up to 500MB of available disk space (depending on components installed)
  • Powered USB Port
  • Monitor resolution of 1024x768 pixels or higher
  • Latest drivers for video card installed
  • Dual display support requires either 2 video cards or a dual head video card that supports dual video LUTs being loaded
  • Network adaptor installed and driver loaded
  • DVD drive or high-speed internet connection required for software install, download and automatic software update
  • User must have administrator rights to install and uninstall application

LANGUAGE VERSIONS
This product is available in the following languages:

  • Chinese (Simplified)
  • English
  • French
  • German
  • Italian
  • Japanese
  • Korean
  • Portuguese
  • Spanish
  • Russian

i1Pro3 Hardware Specifications

SPECTRAL ENGINE

i1® technology with built-in wavelengths check

Spectral analyser: Holographic diffraction grating with 128-pixel diode array
Spectral Range: 380 - 730 nm

Physical sampling interval: 3.5 nm
Optical resolution: 10 nm
Spectral reporting: 380 ... 730 nm in 10 nm steps

Measurement Frequency in scanning mode: 400 measurements per second

OPTICS
Measurement geometry:
45°/0° ring illumination optics, ISO 13655:2017
Measurement aperture: 8 mm (0.31”) diameter (effective measurement aperture during scanning is depending on the patch size and measurement speed)
Illumination Spot Size: 12 mm (0.47”)

Light source: LED Illumination (including UV)

REFLECTANCE MEASUREMENT
Data Format: Spectral Reflectance [dimensionless]
Measurement Conditions:

  • M0 - UV included - ISO 13655:2017
  • M1 - D50 - ISO 13655:2017
  • M2 - UV excluded - ISO 13655:2017
  • M3 - Polarisation - UV excluded - ISO 13655:2017

OBC: Optical Brightener Compensation (OBC) with i1Profiler software

Calibration: Manual on external ceramic white reference

Measurement Background: white, ISO 13655:2017; for measurements on backup board

Minimal Media Thickness: 3 mm (0.12”) on backup board

Minimal Patch Size In Spot Mode

  • 14 x 14 mm (0.55” x 0.55”) (Width x Height)

Minimal Patch Size In Scanning Mode

  • 16 x 16 mm (0.63” x 0.63”) (Width x Height) with i1iO
  • 16 x 16 mm (0.63” x 0.63”) (Width x Height) with sensor ruler
  • 20 x 16 mm (0.79” x 0.63”) (Width x Height) without sensor ruler
  • 20 x 16 mm (0.79” x 0.63”) (Width x Height) with sensor ruler in M3 Mode
  • 22 x 16 mm (0.87” x 0.63”) (Width x Height) without sensor ruler in M3 Mode

Maximum Scan Length

  • 515mm (20.28”)

Inter-instrument agreement: 0.4 Δ E00* average, 1.0 Δ E00* max. (deviation from X-Rite manufacturing standard at a temperature of 23ºC (73.4ºF) on 12 BCRA tiles (D50, 2º))

Short-term repeatability: 0.1 Δ E00* on white (D50,2°, mean of 10 measurements every 3s on white) spectral radiance [mW/nm/m2/sr], luminance [cd/m2]

EMISSIVE MEASUREMENT
Data format:
Spectral radiance (mW/nm/m2 /sr); Luminance Y (cd/m2)
Measurement range: 0.2 - 5000 cd/m2 on a typical LCD-Monitor
Short-term repeatability: x,y: +/- 0.002 typical (5000°K, 80 cd/m2)

AMBIENT LIGHT MEASUREMENT

Data Format: spectral irradiance [mW/nm/m2], illuminance [lux]

Type: Cosine-corrected diffuse light measurement head

INTERFACE, DIMENSIONS AND WEIGHT

Interface: USB 1.1

Power supply: Device powered by USB. No additional charger or battery required. USB 1.1 high power device.

OPERATING CONDITIONS:
Temperature:
10°C (50°F) – 35°C (95°F)

Humidity: 0% – 80% non-condensing

PHYSICAL DIMENSIONS

i1Pro 3 device: Length 162 mm, width 69 mm, height 64 mm (6.4” x 2.7” x 2.5”)

i1Pro 3 Ruler: Length 591mm , width 122 mm (23.3” x 4.8”)

i1 Backup Board: Length 670 mm, width 452 mm (26.4” x 17.8”)

Weight i1Pro device: 285 g (10.0 oz)

i1BASIC PRO 3 PLUS INCLUDES:

 

i1Pro 3 spectrophotometer (measurement device), calibration plate, ambient light measurement head, polarization filter, monitor holder, positioning target, scanning ruler, backup board, USB cable, i1Profiler software for monitors and projectors, PANTONE Color Manager software, ColorTRUE mobile app, and soft-sided storage case.

 

Vendor: X-Rite

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare